- Wide Ranges: -100kPa…0kPa…200kPa
- Optional 2.5V~5.5V Power Supply
- Gage(Positive&Vacuum) Type
- For Non-corrosive Gas or Air or Liquid
- Calibrated Digital Signal(I2C Interface)Refer to XGZP6869A for Analog signal)
- Temp. Compensated: 0℃~+60℃(32℉~+140℉)
- Current Consumption: 5uA(single measurement)
- Standby Current: <100nA (25°C)
- Wide Ranges: -100kPa…0kPa…1000kPa
- Optional 2.5V~5.5V Power Supply
- Gage(Positive&Vacuum) Type
- For Non-corrosive Gas or Air
- Calibrated Digital Signal(I2C Interface)(Refer to XGZP6877A for Analog signal)
- Temp. Compensated: 0℃~+60℃(32℉~+140℉)
- Current Consumption: 5uA(single measurement)
- Standby Current: <100nA (25°C)
- Wide Ranges: -100kPa…0kPa…200kPa
- Optional 2.5V~5.5V Power Supply
- Gage(Positive&Vacuum) Type
- For Non-corrosive Gas or Air
- Calibrated Digital Signal(I2C Interface)(Refer to XGZP6887A for Analog signal)
- Temp. Compensated: 0℃~+60℃(32℉~+140℉)
- Current Consumption: 5uA(single measurement)
- Standby Current: <100nA (25°C)
- Wide Ranges: -100kPa…0kPa…200kPa
- Optional 1.8V~3.6V Power Supply, Low Consumption.
- Gage(Positive&Vacuum) Type
- For dry Non-corrosive Gas or Air
- Calibrated Digital Signal (I2C Interface)
- Temp. Compensated: 0℃~+60℃ (32℉~+140℉)
- Multiple work mode and FIFO available
- Wide Ranges: -100kPa…0kPa…200kPa
- Optional 3.3V~5.5V Power Supply
- Gage(Positive&Vacuum) Type
- For dry Non-corrosive Gas or Air
- Calibrated Digital Signal(I2C Interface)
- Temp. Compensated: 0℃~+60℃(32℉~+140℉)
- Low Consumption
- Wide Ranges: 300hPa … 1100hPa
- 1.8V~3.6V Power Supply(1.2V~3.6V (VDDIO))
- Absolute Pressure Type
- Current Consumption:60uA
- Standby Current:<100nA (25°C)
- Calibrated Digital Signal (I2C Interface)
- Absolute Pressure Accuracy:±1hPa (8.3m)
- Relative Pressure Accuracy:±0.12hPa (1m)
- Temperature Accuracy:±1°C
- Wide Ranges: 300hPa … 1100hPa
- 1.8V~3.6V Power Supply
- Absolute Pressure Type
- Current Consumption:<80uA(single measurement at 128 OSR)
- Standby Current:<100nA (25°C)
- Calibrated Digital Signal (I2C Interface)
- Absolute Pressure Accuracy:±1hPa (8.3m)
- Relative Pressure Accuracy:±0.12hPa (1m)
- Temperature Accuracy:±1°C
- Pressure range: 300hPa … 1100hPa (+9000m … -500m relating to sea level)
- Temperature Range: -40…+85°C
- Supply voltage: 1.7V … 3.6V (VDD), 1.2V….. 3.6V (VDDIO)
- Relative accuracy: ±0.06hPa, equiv. to ±0.5 m
- Absolute accuracy: typ. ±1hPa (300hPa … 1100hPa)
- Measurement time: Typical: 28 ms. Minimum: 3 ms.
- Average current consumption: High precision: 60 µA, Low power: 3 µA, Standby: <1 µA.
- I2C interface, Embedded 24-bit ADC
- FIFO: Stores latest 32 pressure or temperature measurements.
- Pb-free, halogen-free and RoHS complian
- Water resistance degree: water resistance rating of 100 meters
- Wide Ranges: 0kPa~100kPa…2500kPa
- 1.8V~3.3V Power Supply, low consumption
- Absolute Pressure Type
- For Non-corrosive Gas or Air
- Calibrated Digital Signal (I2C Interface)
- Current Consumption:<80uA (single measurement at 128 OSR)
- Standby Current:<100nA (25°C)
- Temp. Compensated
- Temperature Accuracy:±1°C
- Wide Ranges: 0kPa~100kPa…3000kPa
- 1.8V~3.3V Power Supply,low consumption
- Absolute Pressure Type
- For Non-corrosive Gas or Air or Liquid
- Calibrated Digital Signal (I2C Interface)
- Current Consumption:<80uA (single measurement at 128 OSR)
- Standby Current:<100nA (25°C)
- Temp. Compensated
- Temperature Accuracy:±1°C
- Wide Ranges: 0kPa~100kPa…2500kPa
- Optional 3.3V~5.5V Power Supply
- Absolute Pressure Type
- For Non-corrosive Gas or Air
- Calibrated Digital Signal (I2C Interface)(Refer to XGZP6818A for Analog signal)
- Mutliple Working Methods
- Standby Current:<100nA (25°C)
- Temparature Accuracy: ±1°C
- Wide Ranges: 0kPa~100kPa…2500kPa
- Optional 3.3V~5.5V Power Supply
- Absolute Pressure Type
- For Non-corrosive Gas or Air or Liquid
- Calibrated Digital Signal (I2C Interface)(Refer to XGZP6826A for Analog signal)
- Temp. Compensated: 0℃~+60℃ (32℉~+140℉)
- Current Consumption:5uA(single measurement)
- Standby Current:<100nA (25°C)
Start typing to see products you are looking for.