Pressure Switch Sensor XGZP6877D

  • Wide Ranges: -100kPa…0kPa…1000kPa
  • Optional 2.5V~5.5V Power Supply
  • Gage(Positive&Vacuum) Type
  • For Non-corrosive Gas or Air
  • Calibrated Digital Signal(I2C Interface)(Refer to XGZP6877A for Analog signal)
  • Temp. Compensated: 0℃~+60℃(32℉~+140℉)
  • Current Consumption: 5uA(single measurement)
  • Standby Current: <100nA (25°C)
Share on whatsapp
Share on email
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Description

Pressure switch sensor XGZP6877D is for high volume application at an affordable cost and perfect performance. Customized calibration parameter (e.g.pressure range etc.) are available.

 

PRESSURE SWITCH SENSOR XGZP6877D ESSENTIAL DETAILS

ManufacturerCFSensor
Product CategoryPressure Sensor
SeriesXGZP6877D
Model NumberAs Order Guide
Pressure Range-100kPa…0kPa…1000kPa
Pressure TypeGauge
Power Supply2.5~5.5
Output TypeI2C interface
Output24 bits
Accuracy±2.5%(customizable)
Measured MediaAir or Non-corrosive Gas
Temp. Compensated0~60°C
Operating Temp-30~120°C
PackagePlastic Tube

 

APPLICATIONS

  • Medical&Healthy: e.g. ventilators, CPAP, NPWT, DVT, blood analysis, blood pressure monitoring, drug dosing, hospital beds, oxygen concentrators, patient monitoring, sleep apnea equipment, urine analyzers and wound therapy, breast pumps, massage device etc.
  • Consumer&Household: e.g. Robot, UAV, wearable device, coffee makers, washing machines, vacuum cleaners, hand dryers, air pump, air beds etc.
  • Industrial&Automation: e.g. HVAC, flow and liquid level measurement, process control and monitoring, life sciences, pressure switch and meter, IoT and automotive application etc.

 

INTRODUCTION

Pressure switch sensor XGZP6877D is a prefect silicon pressure sensor offering a ratiometric digital data(I2C interface) for reading differential pressure over the specified full scale pressure span.

The XGZP6877D pressure switch sensor incorporates a silicon piezoresistive pressure sensor chip and an interior signalconditional Application Specific Integrated Circuit(ASIC) in a SOP8 package, which can be mounted directly on a standard PCB.

The XGZP6877D pressure switch sensor is fully calibrated and temperature compensated for specified span, so XGZP6877D pressure sensor satisfy the perfect accuracry, which is designed for a wide range of application in medical care&health, home appliances, consumer electronic, industry, automotive, loT and other pneumatic devices etc by utilizing a microcontroller or microprocessor with D/A inputs.

 

DIMENSION (Unit:mm)

pressure switch sensor xgzp6877d dimension

 

ORDER GUIDE (100kPa=0.1MPa=1bar≈14.5PSI)

pressure switch sensor xgzp6877d order guide

Note: Custom requirement or parameter, please consult CFSensor and comment custom code herewith Part number.

 

PRESSURE RANGE EXAMPLE

Please consult CFSensor whether required pressure range is under normal production before place order.

Notes:
1. Unit conversion: 1000hPa=1000mbar≈750mmHg≈100kPa≈14.5PSI≈10mH2O≈1bar=0.1MPa;
2. Available for more custom pressure range e.g. -7~7kPa, , 0-1500kPa etc,.

pressure switch sensor xgzp6877d routine pressure range

 

More information about pressure switch sensor XGZP6877D, refer to Datasheet or contact CFSensor

XGZP6877D Pressure Sensor V2.5.PDF

SAFETY NOTES & WARRANTY

SAFETY NOTES

Using these sensors products may malfunction due to external interference and surges, therefore, please confirm the performance and quality in actual use. Just in case, please make a safety design on the device (fuse, circuit breaker, such as the installation of protection circuits, multiple devices, etc.), so it would not harm life, body, property, etc even a malfunction occurs. To prevent injuries and accidents, please be sure to observe the following items:

  • The driving current and voltage should be used below the rated value.
  • Please follow the terminal connection diagram for wiring. Especially for the reverse connection of the power supply, it will cause an accident due to circuit damage such as heat, smoke, fire, etc.
  • In order to ensure safety, especially for important uses, please be sure to consider double safety circuit configuration.
  • Do not apply pressure above the maximum applied pressure. In addition, please be careful not to mix foreign matter into the pressure medium. Otherwise, the sensor will be discarded, or the media will blew out and cause an accident.
  • Be careful when fixing the product and connecting the pressure inlet. Otherwise, accidents may occur due to sensor scattering and the blowing out of the media.
  • If the sensor come with sharp PIN, please be careful not to hurt your body when using it.

WARRANTY

The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. CFSensor reserves the right to make changes without further notice to any product herein.

CFSensor makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does CFSensor assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. CFSensor does not convey any license under its patent rights nor the rights of others.

Start typing to see products you are looking for.

Contact Us

[ninja_form id=1]