XGZP191 (MPX2010GP, MPX2050GP, MPX2053GP, MPX2100GP, MPX2200GP, MPX2202GP Alternative Parts)

  • Range: 0~10/50/100/200kPa
  • MEMS technology, Solid-state reliability
  • Barb inlet pipe
  • Laser trimmed mV output
  • Temperature compensated
  • Working temp.: -30℃~+85℃(-22℉~+185℉)
  • Gage pressure type
  • Easy to use and embed in OEM equipment
Share on whatsapp
Share on email
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Description

ESSENTIAL DETAILS

MPX2010 vs MPX2050 vs MPX2053 vs MPX2100 vs MPX2200 vs MPX2202 vs XGZP191 Comparison

ManufacturerCFSensorNXPNXP NXPNXPNXPNXP
Product CategoryPressure SensorPressure SensorPressure SensorPressure SensorPressure SensorPressure SensorPressure Sensor
SeriesXGZP191MPX2010MPX2050MPX2053MPX2100MPX2200MPX2202
Model NumberAs Order GuideMPX2010GPMPX2050GPMPX2053GPMPX2100GPMPX2200GPMPX2202GP
Pressure Range0~10/50/100/200kPa0KPa~10KPa0KPa~50KPa0KPa~50KPa0KPa~100KPa0KPa~200KPa0KPa~200KPa
Pressure TypeGaugeGaugeGaugeGaugeGaugeGaugeGauge
Power Supply10Vdc1V ~ 16V1V ~ 16V1V ~ 16V1V ~ 16V1V ~ 16V1V ~ 16V
Output TypeNon-amplified AnalogAnalogAnalogAnalogAnalogAnalogAnalog
OutputmV(millivolt)0 mV ~ 25 mV (10V)0 mV ~ 40 mV (10V)0 mV ~ 40 mV (10V)0 mV ~ 40 mV (10V)0 mV ~ 40 mV (10V)0 mV ~ 40 mV (10V)
Bridge Resistance5kΩ
Measured MediaAir or Non-corrosive Gas
Temp. CompensatedYesYesYesYesYesYesYes
Operating Temp-30℃~+85℃(-22℉~+185℉)-40°C~125°C-40°C~125°C-40°C~125°C-40°C~125°C-40°C~125°C-40°C~125°C
PackageTrayTrayTrayTrayTrayTrayTray

 

APPLICATIONS

  • Medical & Healthcare
  • Industrial & Automation
  • Domestic Appliance
  • Consumer Electronic
  • Automotive Electronic

 

INTRODUCTION

XGZP191 is a through hole mounted pressure sensor based on CFSensor silicon piezo-resistive pressure sensor die. The sensor die is bonded on a substrate with a plastic cap and packaged in a 4-pin housing. The sensor’s zero output, full-scale output, temperature drift and other parameters have been calibrated and compensated by laser trimming. The sensor generates a high-precision standard voltage output signal proportional to the supply voltage.

The small size and high reliability of integration make this sensor a simple and economical choice for high volume application in a variety of industries. With standard PIN interface, XGZP191 is easy for users to install by through-hole mounting.

The XGZP191 pressure sensor is intended for use with non-corrosive gas or air. It is highly prohibited to choke the side of pressure diaphragm during actual application. Please consult us if a pressure medium other then air is to be used.

 

DIMENSION (Unit:mm Unspecified Tolerances:±0.1mm)

191 DIMENSION

 

ORDER GUIDE

191 ORDER GUIDE

 

More about the difference between MPX2010GP, MPX2050GP, MPX2053GP, MPX2100GP, MPX2200GP, MPX2202GP and XGZP191, refer to Datasheet or contact CFSensor

XGZP191 Pressure Sensor-V1.7.PDF

SAFETY NOTES & WARRANTY

SAFETY NOTES

Using these sensors products may malfunction due to external interference and surges, therefore, please confirm the performance and quality in actual use. Just in case, please make a safety design on the device (fuse, circuit breaker, such as the installation of protection circuits, multiple devices, etc.), so it would not harm life, body, property, etc even a malfunction occurs. To prevent injuries and accidents, please be sure to observe the following items:

  • The driving current and voltage should be used below the rated value.
  • Please follow the terminal connection diagram for wiring. Especially for the reverse connection of the power supply, it will cause an accident due to circuit damage such as heat, smoke, fire, etc.
  • In order to ensure safety, especially for important uses, please be sure to consider double safety circuit configuration.
  • Do not apply pressure above the maximum applied pressure. In addition, please be careful not to mix foreign matter into the pressure medium. Otherwise, the sensor will be discarded, or the media will blew out and cause an accident.
  • Be careful when fixing the product and connecting the pressure inlet. Otherwise, accidents may occur due to sensor scattering and the blowing out of the media.
  • If the sensor come with sharp PIN, please be careful not to hurt your body when using it.

WARRANTY

The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. CFSensor reserves the right to make changes without further notice to any product herein.

CFSensor makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does CFSensor assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. CFSensor does not convey any license under its patent rights nor the rights of others.

Start typing to see products you are looking for.

Contact Us