XGZP6872A (MPX5700A, MPX4115A Alternative Parts)

  • Wide Ranges: 0~100…1000kPa
  • Absolute Pressure Type
  • For Non-corrosive Gas or Air
  • Calibrated Amplified Analog Signal
  • Temp. Compensated: 0℃~+85℃(32℉~+185℉)
  • Direct Application,Low Cost
  • Customization available
Share on whatsapp
Share on email
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Description

XGZP6872A pressure sensor is for high volume application at an affordable cost and perfect performance. Customized calibrations (working voltage,output voltage, and pressure range) are available.

 

ESSENTIAL DETAILS

MPX5700A vs MPX4115A vs XGZP6872A Comparison

ManufacturerCFSensorNXPNXP
Product CategoryPressure SensorPressure SensorPressure Sensor
SeriesXGZP6872AMPX5700MPX4115A
Model NumberAs Order GuideMPX5700AMPX4115A
Pressure Range0kPa~100kPa…700kPa0KPa~700KPa15KPa~115KPa
Pressure TypeAbsoluteAbsoluteAbsolute
Power Supply4.75V ~ 5.25V4.75V ~ 5.25V4.85V ~ 5.35V
Output TypeAnalogAnalogAnalog
Output0.2 V ~ 4.7 V0.2 V ~ 4.7 V0.2 V ~ 4.8 V
Accuracy±2.5%±2.5%±1.5%
Measured MediaAir or Non-corrosive Gas
Temp. CompensatedYesYesYes
Operating Temp-30~120°C-40°C~125°C-40°C~125°C
PackageTrayTrayTray

 

APPLICATIONS

  • Tank level measurement, Liquid level measurement, White goods(e.g.washer), Heating, Ventilation, Air conditioning, Filter detection, Industrial controls.
  • Medical gas control system, Hospital beds, Massage device, Engine control/manifold absolute pressure (MAP), Green gas ( LPG and CNG) control and measurement.
  • Weather station and weather reporting device barometers, Sport and leisure equipment, Vacuum measurement, pneumatic device, Absolute pressure meter.

 

INTRODUCTION

XGZP6872A is a prefect silicon pressure sensor offering a ratiometric analog interface for reading absolute pressure over the specified full scale pressure span and temp.range.

The XGZP6872A incorporates a silicon piezoresistive pressure sensor chip and an interior signal-conditional Application Specific Integrated Circuit(ASIC) in a unibody package with long 6 PIN, which can be mounted freely from different direction.

The XGZP6872A is fully calibrated and temperature compensated for offset,sensitivity, temperature and non-linearity, so XGZP6872A pressure sensor satisfy the prefect repeatability,linearity, stability and sensibility, which can be applied directly in medical&healthy, home appliances, consumer electronic, industry, automotive, loT and other pneumatic devices etc;.

 

DIMENSION (Unit:mm)

xzp6872a dimension

 

ORDER GUIDE (100kPa=0.1MPa=1bar≈14.5PSI)

xzp6872a order guide

Note:
1. For specific output e.g 0.2~4.8, signify output figure behind part number, e.g. : XGZP6872A15115KPA0248
2. Custom requirement or parameter, please consult CFSensor for custom code(e.g custom pressure range etc,.)

 

PRESSURE RANGE EXAMPLE

Please consult CFSensor whether required pressure range is under normal production before place order.

Notes:
1. Unit conversion: 1000hPa=1000mbar≈750mmHg≈100kPa≈14.5PSI≈10mH2O≈1bar=0.1MPa;
2. Available for more custom pressure range e.g. 0~3.92kPa,-2~2kPa,0~6kPa, 0~25kPa etc,.

mpx5700a, mpx4115a alternative parts xzp6872a pressure range example

 

More about the difference between MPX5700A, MPX4115A and XGZP6872A, refer to Datasheet or contact CFSensor

XGZP6872A Pressure Sensor V1.2..PDF

SAFETY NOTES & WARRANTY

SAFETY NOTES

Using these sensors products may malfunction due to external interference and surges, therefore, please confirm the performance and quality in actual use. Just in case, please make a safety design on the device (fuse, circuit breaker, such as the installation of protection circuits, multiple devices, etc.), so it would not harm life, body, property, etc even a malfunction occurs. To prevent injuries and accidents, please be sure to observe the following items:

  • The driving current and voltage should be used below the rated value.
  • Please follow the terminal connection diagram for wiring. Especially for the reverse connection of the power supply, it will cause an accident due to circuit damage such as heat, smoke, fire, etc.
  • In order to ensure safety, especially for important uses, please be sure to consider double safety circuit configuration.
  • Do not apply pressure above the maximum applied pressure. In addition, please be careful not to mix foreign matter into the pressure medium. Otherwise, the sensor will be discarded, or the media will blew out and cause an accident.
  • Be careful when fixing the product and connecting the pressure inlet. Otherwise, accidents may occur due to sensor scattering and the blowing out of the media.
  • If the sensor come with sharp PIN, please be careful not to hurt your body when using it.

WARRANTY

The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. CFSensor reserves the right to make changes without further notice to any product herein.

CFSensor makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does CFSensor assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. CFSensor does not convey any license under its patent rights nor the rights of others.