XGZP6899A (MPXV7002DP, MPXV5004DP, MPXV5010DP/MP3V5050GP, MPXV5050DP/MP3V5050DP, MPXV5100DP, MPXV4006DP, MPXV7025DP Alternative Parts)

  • Wide Ranges: -100kPa…-0.5~0~0.5…700kPa(show in Pressure Range Example)
  • Differential Pressure Type
  • For Non-corrosive Gas or Air
  • Optional 5V and 3.3V Voltage
  • Calibrated Amplified Analog Signal(Refer to XGZP6899D for I2C interface)
  • Temp. Compensated: 0℃~+60℃(32℉~+140℉)
  • Direct Application, Low Cost.
Share on whatsapp
Share on email
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Description

ESSENTIAL DETAILS

MPXV7002DP vs MPXV5004DP vs MPXV5010DP/MP3V5050GP vs MPXV5050DP/MP3V5050DP vs MPXV5100DP vs MPXV4006DP vs MPXV7025DP vs XGZP6899A Comparison

ManufacturerCFSensorNXPNXPNXPNXPNXPNXPNXP
Product CategoryPressure SensorPressure SensorPressure SensorPressure SensorPressure SensorPressure SensorPressure SensorPressure Sensor
SeriesXGZP6899AMPXV7002MP3V5004MP3V5010MP3V5050MPXV5100MPXV4006MPXV7025
Model NumberAs Order GuideMPXV7002DPMP3V5004DPMPXV5010DP/ MP3V5050GPMPXV5050DP /MP3V5050DPMPXV5100DPMPXV4006DPMPXV7025DP
Pressure Range-100kPa…-0.5kPa~0kPa~0.5kPa…700kPa-2KPa~2KPa0KPa~392KPa0KPa~10KPa0KPa~50KPa0KPa~100KPa0KPa~6KPa0KPa~25KPa
Pressure TypeDifferentialDifferentialDifferentialDifferentialDifferentialAbsoluteDifferentialDifferential
Power Supply5V/3.3V5V3V5V/3V5V/3V5V5V5V
Output TypeAmplified AnalogAnalogAnalogAnalogAnalogAnalogAnalogAnalog
Output0.5~4.5V/0.2~2.7V0.5 V ~ 4.5 V0.6 ~ 1.8V(3kPA)0.2 ~ 4.7V/0.24 ~ 2.94V0.2 ~ 4.7V/0.12 ~ 2.8V0.2 V ~ 4.7 V0.2 V ~ 4.8 V0.2 V ~ 4.7V
Accuracy±2.5%(customizable)±2.5%±2.5%±5%±2.5%±2.5%±5%±5%
Measured MediaAir or Non-corrosive Gas
Temp. Compensatedp0℃~+60℃(32℉~+140℉)10~60°C10~60°C-40°C~125°C-40°C~125°C0~85°C10~60°C10~60°C
Operating Temp-30~100°C10~60°C0~85°C-40°C~125°C-40°C~125°C-40°C~125°C-40°C~125°C10~60°C
PackagePlastic TubeTrayTrayTrayTrayTrayTrayTray

Notice: Pin definitions vary, refer to datasheet only.

 

APPLICATIONS

  • Medical&Healthcare
  • Industrial&Automation
  • Domestic Appliance
  • Consumer Electronic
  • Automotive Electronic

 

INTRODUCTION

XGZP6899A is a prefect silicon pressure sensor offering a ratiometric analog interface for reading differential pressure over the specified full scale pressure span and temp.range.

The XGZP6899A incorporates a silicon piezoresistive pressure sensor chip and an interior signal-conditional Application Specific Integrated Circuit(ASIC) in a SOP8 package with two air vents, which can be mounted directly on a standard PCB.

The XGZP6899A is fully calibrated and temperature compensated for offset,sensitivity, temperature and non-linearity, so XGZP6899A pressure sensor satisfy the prefect repeatability,linearity, stability and sensibility, which can be applied directly in medical&healthy, home appliances, consumer electronic, industry, automotive, loT and other pneumatic devices etc.

XGZP6899A pressure sensor is for high volume application at an affordable cost and perfect performance.

Customized calibrations(working voltage,output voltage,and pressure range) are available.

 

DIMENSION (Unit:mm)

 

6899A DIMENSION

ORDER GUIDE (100kPa=0.1MPa=1bar≈14.5PSI)

6899A ORDER GUIDE

PRESSURE RANGE EXAMPLE

6899A PRESSURE RANGE

 

More about the difference between MPXV7002DP, MPXV5004DP, MPXV5010DP/MP3V5050GP, MPXV5050DP/MP3V5050DP, MPXV5100DP, MPXV4006DP, MPXV7025DP and XGZP6899A, refer to Datasheet or contact CFSensor

XGZP6899A Pressure Sensor V2.8.PDF

SAFETY NOTES & WARRANTY

SAFETY NOTES

Using these sensors products may malfunction due to external interference and surges, therefore, please confirm the performance and quality in actual use. Just in case, please make a safety design on the device (fuse, circuit breaker, such as the installation of protection circuits, multiple devices, etc.), so it would not harm life, body, property, etc even a malfunction occurs. To prevent injuries and accidents, please be sure to observe the following items:

  • The driving current and voltage should be used below the rated value.
  • Please follow the terminal connection diagram for wiring. Especially for the reverse connection of the power supply, it will cause an accident due to circuit damage such as heat, smoke, fire, etc.
  • In order to ensure safety, especially for important uses, please be sure to consider double safety circuit configuration.
  • Do not apply pressure above the maximum applied pressure. In addition, please be careful not to mix foreign matter into the pressure medium. Otherwise, the sensor will be discarded, or the media will blew out and cause an accident.
  • Be careful when fixing the product and connecting the pressure inlet. Otherwise, accidents may occur due to sensor scattering and the blowing out of the media.
  • If the sensor come with sharp PIN, please be careful not to hurt your body when using it.

WARRANTY

The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. CFSensor reserves the right to make changes without further notice to any product herein.

CFSensor makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does CFSensor assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. CFSensor does not convey any license under its patent rights nor the rights of others.

Start typing to see products you are looking for.

Contact Us