    Digital TO-46 Thermopile Temperature Sensor XGZT2613

    • Standard I2C interface
    • High-precision digital temperature measuring sensor
    • Temperature calibrated, easy to implement
    • Direct temperature measurement without peripheral circuits
    • MEMS thermopile technology
    • High response rate, and a fast response time
    • A 5.5 μ m long-pass filter
    • TO-46 metal tube shell package

    I2C Thermopile Sensor XGZT2614 (MLX90614 Infrared Thermometer Alternative Parts)

    • Standard I2C interface
    • High-precision digital temperature measuring sensor
    • Temperature calibrated, easy to implement
    • Direct temperature measurement without peripheral circuits
    • 30 to 50CM measurement distance
    • High response rate, and a fast response time
    • A 5.5 μ m long-pass filter
    • TO-39 metal tube shell package

    Differential Pressure Meter XGZP9091

    • High precision with internal temperature compensation
    • High sensitivity and high resolution
    • Reliable quality, stable performance, and low cost
    • Outputs available: 4-20mA, 0-5V/10V, RS485 communication
    • Configurable parameters via buttons
    • Over-range alarm indicator light reminder function
    • Compact size and simple installation

    Gas Mass Flow Meter XGZF6000

    • High precision and resolution with internal temperature compensation
    • High sensitivity and high resolution
    • Reliable quality, stable performance, and low cost
    • LCD display, RS485 communication
    • Configurable parameters via buttons
    • Over-range alarm indicator light reminder function
    • Standard G or NPT thread for easy installation

    Gas Mass Flow Switch XGZF7000 (PF2MC7 Flow Switch Alternative Parts)

    • 5~500L/min;10~1000L/min
    • Dry Air、N2
    • LCD Display, 3 Colour, 3 Screen
    • Measurable Flow Ratio: 100:1
    • Minimum Flow Increment: 1L/min
    • Display Layer Rotatable
    • NPN/PNP Switch Function
    • Adjustable Response Speed(0.05S~5S)
    • Pressure-Resistance 12bar
    • Reliable Quality with Low Cost

    XGZF5000 Compact Analog Air Flow Sensor for Medical Ventilators and CPAP Machines

    • MEMS mass gas flow technology
    • Wide range from 5 to 300SLM
    • Analog or Digital output optional
    • Unidirectional and bidirectional flow optional
    • Low working voltage optional
    • Fast Response
    • High sensitivity&accuracy
    • Reliable and stable performance

    XGZF5000 High Precision Digital Air Flow Sensor for HVAC Systems and Air Monitoring

    • MEMS mass gas flow technology
    • Wide range from 5 to 300SLM
    • Analog or Digital output optional
    • Unidirectional and bidirectional flow optional
    • Low working voltage optional
    • Fast Response
    • High sensitivity&accuracy
    • Reliable and stable performance

    GZC6800A Analog Output Current Sensor

    • ±0.5 % nonlinear error over the entire temperature range
    • Fast output step response time: 1.2 μs
    • 300kHz signal bandwidth
    • Powered by 5.0V DC power supply
    • Working Temperature -40℃ to 125 ℃
    • Rated current detection range: (bidirectional) —± 5 A~± 50 A
    • Detecting AC and DC current signals
    • Current proportional voltage output mode
    • Extremely stable zero-current output voltage

    XGZC6201 ±120A Current Sensor Transducer

    • ±0.5% linearity over full temperature range
    • Fast output step response time: 1.8μs
    • 240kHz signal bandwidth
    • 5.0V DC power supply
    • -40°C to 105°C operating temperature
    • Rated current detection range: (bidirectional) — ±10A~±120A
    • Detects AC and DC current signals
    • Power-independent fixed output mode
    • Extremely stable quiescent output voltage
    • Built-in reference voltage output

    XGZC6201 ±20A Hall Effect Current Transducer

    • ±0.5% linearity over full temperature range
    • Fast output step response time: 1.8μs
    • 240kHz signal bandwidth
    • 5.0V DC power supply
    • -40°C to 105°C operating temperature
    • Rated current detection range: (bidirectional) — ±10A~±120A
    • Detects AC and DC current signals
    • Power-independent fixed output mode
    • Extremely stable quiescent output voltage
    • Built-in reference voltage output

    XGZC6201 ±50A LEM Current Transducer Sensor

    • ±0.5% linearity over full temperature range
    • Fast output step response time: 1.8μs
    • 240kHz signal bandwidth
    • 5.0V DC power supply
    • -40°C to 105°C operating temperature
    • Rated current detection range: (bidirectional) — ±10A~±120A
    • Detects AC and DC current signals
    • Power-independent fixed output mode
    • Extremely stable quiescent output voltage
    • Built-in reference voltage output

    XGZC6201 ±80A AC/DC Current Sensor

    • ±0.5% linearity over full temperature range
    • Fast output step response time: 1.8μs
    • 240kHz signal bandwidth
    • 5.0V DC power supply
    • -40°C to 105°C operating temperature
    • Rated current detection range: (bidirectional) — ±10A~±120A
    • Detects AC and DC current signals
    • Power-independent fixed output mode
    • Extremely stable quiescent output voltage
    • Built-in reference voltage output

    XGZC6201 HLSR-P ±10A Alternating Current Sensor

    • ±0.5% linearity over full temperature range
    • Fast output step response time: 1.8μs
    • 240kHz signal bandwidth
    • 5.0V DC power supply
    • -40°C to 105°C operating temperature
    • Rated current detection range: (bidirectional) — ±10A~±120A
    • Detects AC and DC current signals
    • Power-independent fixed output mode
    • Extremely stable quiescent output voltage
    • Built-in reference voltage output

    Water Pressure Sensor XGZP6858D

    • Wide Ranges: 0kPa~100kPa…700kPa(show in Pressure Range Example)
    • 2.7V~5.5V Power Supply
    • Absolute Pressure Type
    • For Non-corrosive Gas or Air or Liquid
    • Calibrated Digital Signal(I2C Interface)(Refer to XGZP6858A for Analog signal)
    • Temp. Compensated: 0℃~+60℃(32℉~+140℉)
    • Temperature Measurable
    • Affordable Cost, Easy-to-use

    Waterproof Barometric Pressure Sensor​ XGZP6808D

    • Pressure range: 300hPa … 1100hPa (+9000m … -500m relating to sea level)
    • Temperature Range: -40…+85°C
    • Supply voltage: 1.7V … 3.6V (VDD), 1.2V….. 3.6V (VDDIO)
    • Relative accuracy: ±0.06hPa, equiv. to ±0.5 m
    • Absolute accuracy: typ. ±1hPa (300hPa … 1100hPa)
    • Measurement time: Typical: 28 ms. Minimum: 3 ms.
    • Average current consumption: High precision: 60 µA, Low power: 3 µA, Standby: <1 µA.
    • I2C interface, Embedded 24-bit ADC
    • FIFO: Stores latest 32 pressure or temperature measurements.
    • Pb-free, halogen-free and RoHS complian
    • Water resistance degree: water resistance rating of 100 meters